Hevylite® immunoglobulin heavy chain/light chain analysis
Hevylite® (HLC), a new assay now available from Binding Site, promises to transform the way patients with B cell dyscrasias are managed, just as the Freelite® assay has done.
In summary Hevylite® assays offer:
- Higher sensitivity than serum protein electrophoresis for quantifying monoclonal immunoglobulins
- Numerical results for patients at a sensitivity as high as or better than immunofixation electrophoresis
- Clinical value when monitoring patients with monoclonal gammopathies
- HLC ratios which have a greater range of changes than monoclonal immunoglobulin measurements because the non-tumour immunoglobulin allows assessment of immunosuppression
- HLC ratios which are not affected by changes in blood volume, haematocrit and variable metabolism (via FcRn receptors for IgG) that affect current assays for serum immunoglobulins
- HLC ratios that provide information about the tumour selective killing rate versus non-tumour plasma cell kill rates. The assessment of selective tumour killing rates may help with decision making regarding effective chemotherapies
Ordering information for Hevylite® assays
|
|
| Target epitopes (in black) for Hevylite® antibodies are on the constant regions between the heavy and light chains of immunoglobulin molecules |
As with Freelite® assays, the reagents used to make the Hevylite® tests are polyclonal antibodies produced in sheep. Immunisation and adsorption techniques are designed to ensure no cross-reactivity. So, for example, IgGκ reagents do not react with free κ or IgGλ, or any other immunoglobulins.
There are 4 Hevylite® epitope regions per immunoglobulin molecule - one on each side of the heavy chain / light chain contact regions and the same on the other arm of the molecule. Because there are 4 epitope regions per molecule, immune complexes readily form with immunoglobulins in the patient's serum. This is needed to produce good homogeneous immunoassays that are suitable for nephelometric and turbidimetric automated laboratory analysers.
![]() |
| Heavy chain/light chain pairs of IgG, IgA and IgM molecules showing the target epitopes for Hevylite® immunoassays in black. |
Typical analytical tests for monoclonal gammopathies are serum protein electrophoresis (SPE or SPEP) with scanning densitometry and/or immunofixation electrophoresis (IFE) together with serum free light chain immunoassays. While SPE is a simple, low cost test, it is not very sensitive and quantification of proteins at low concentrations (1-3g/L) is inaccurate.
This is particularly apparent for monoclonal IgA since its anodal electrophoretic migration positions it over other bands such as transferrin. Improved sensitivity is achieved with IFE but IFE is a non-quantitative assay. Nephelometry is also used for immunoglobulin measurements and is analytically accurate down to low concentrations. However, patients' samples also contain non-tumour polyclonal immunoglobulins of both κ and λ types that are included in the analysis. This means results are clinically inaccurate at normal serum concentrations.
Furthermore, assessments of monoclonal IgG are unreliable because of variable catabolism as FcRn recycling receptors that bind albumin and IgG become saturated or reduced by chemotherapy.
Binding Site SPAplus Analyser
|
Description
|
Pack
|
Code
|
|
Binding Site SPAplus
NEW Hevylite® IgG Kappa kit** |
50 test | NK621.S |
|
Binding Site SPAplus
NEW Hevylite® IgG Lambda kit** |
50 test | NK622.S |
|
Binding Site SPAplus
Hevylite® IgA Kappa kit** |
50 test
|
NK623.S
|
|
Binding Site SPAplus
Hevylite® IgA Lambda kit** |
50 test | NK624.S |
| Binding Site SPAplus NEW Hevylite® IgM Kappa kit** |
50 test | NK625.S |
| Binding Site SPAplus NEW Hevylite® IgM Lambda kit** |
50 test | NK626.S |
More kits in the range will become available late 2010.
Siemens Analysers/Platforms
|
Description
|
Pack
|
Code
|
|
Siemens BN™II
Hevylite® IgG Kappa kit** |
50 test
|
NK621.T
|
|
Siemens BN™II
Hevylite® IgG Lambda kit** |
50 test
|
NK622.T
|
|
Siemens BN™II
Hevylite® IgA Kappa kit** |
50 test
|
NK623.T
|
|
Siemens BN™II
Hevylite® IgA Lambda kit** |
50 test
|
NK624.T
|
|
Siemens BN™II
Hevylite® IgM Kappa kit** |
50 test | NK625.T |
|
Siemens BN™II
Hevylite® IgM Lambda kit** |
50 test | NK626.T |
** Please enquire regarding FDA status








What is Hevylite®
What is Hevylite®